Fire Services



PLEASE CALL US AT 02 9330 7000 TO RECEIVE A FREE, NO OBLIGATION QUOTE
Please select a product below:

Overview

As a fire can start anywhere at anytime, your fire systems must be functional and operational at all times. Through our routine servicing, our technicians will be able to provide you with the servicing that your fire systems require and through our technicians and experts advice, we will be able to offer you the right advice for ongoing maintenance of your fire system. We have the capacity to carry out Routine Maintenance and servicing of wide range of fire systems.

The maintenance of fire systems will be carried out strictly in accordance with relevant Australia Standards. The size of our business give us the ability to provide more personalized service, hence in the event of emergency, we will be able to provide rapid response to our clients.

We have got fully trained and qualified staff. Our technicians are trained and retrained frequently enough to keep up with the change in Australian Standards to maintain compliance of the fire systems we service.

We are available 24-7 to cater for the emergency needs of our customers.

For those people who are responsible for work places, the requirement for maintenance of essential services is very strict. This includes the responsibility of maintaining equipment to the relevant standard, keeping maintenance records, and completing necessary compliance reports.

RFD's routine maintenance programme ensures that your fire equipment and systems are regularly tested, serviced and maintained in accordance with Australian Standards.

Fire Extinguishers 
Fire Extinguishers

Fire extinguishers need to be serviced on six monthly frequency. There are other higher routines to be carried out for e.g. 5 yearly pressure test and recharge. Foam Extinguishers need to be recharged once every 12 months.

Fire Blankets 
Fire Blankets

Fire Blankets need to be serviced once every six months.

Hose Reels 
Hose Reels

Hose reels need to be inspected once every six months.

Fire Hydrants 
Fire Hydrants

Fire Hydrants need to be tested every six months. However, once a year it requires flow test to be carried out. On 5 yearly basis, Hydrostatic test is to be carried out to ensure the strength of hydrant piping is enough to hold the prescribed water pressure.

Sprinkler Systems 
Sprinkler Systems

Sprinkler systems need to be tested on weekly or monthly basis depending upon their elegibility. However more extensive test is carried out on six monthly and annual basis. Sprinkler valves need to be overhauled once every 3 years.

Electric Pump 
Electric Pump

Whether it is a hydrant or sprinkler pump, all electric pump must be tested on monthly basis followed by more detailed testing on six monthly and annual basis. Pump overhaul is required to be carried out on 5 yearly basis.

Diesel Pump 
Diesel Pump

Whether it is a hydrant or sprinkler pump, all diesel pump must be test on at least monthly or weekly basis depending on their eligibility. More detailed tests are carried out on six monthly and annual basis (including pump service). Pump overhaul is required to be carried out on 5 yearly basis.

Fire Detection System 
Fire Detection System

Fire Detection system is required to be tested on monthly basis. More detailed testing is carried out on six monthly and annual basis. On annual basis, a separate test is carried out on 50% of the smoke and 20% of thermal detectors.

EWIS (Emergency Warning and Intercommunication System) 
EWIS (Emergency Warning and Intercommunication System)

Emergency Warning and Intercommunication System (EWIS) is tested on monthly basis. A more detailed testing is carried out on six monthly and annual basis.

Emergency 
Emergency

Emergency and exit lights are tested on six monthly basis. A full function test of 90 minutes is carried out in which power supply to each light is disconnected and their performance is observed for 90 minutes. Any light that do not illuminate for 90 minutes on battery is deemed to fail the test. Necessary rectification is to be carried out in order to meet the compliance requirement.

Fire Doors 
Fire Doors

Common Area Fire Doors need to be tested on quarterly basis and fire doors to residential apartment need to be checked once every 12 months. The purpose of this test is to ensure that the gap between the door leaf and the frame has not exceeded the prescribed allowable gap. There are other checks carried out such as integrity of door hardware, door tags, etc.

Pressure Test 
Pressure Test

Hydrostatic test of all pressure vessels.